My first thought would be that it is not locking tight against the variator sleeve. IOW, the total variator length is not as long as the crank on that side.

To test my theory, remove the belt and properly retighten the variator, then check if it has clearance between the outer pulley and the sleeve with a feeler gauge. There should be none.